Nanjing Runze Fluid Control Equipment Co., LTD.
Nanjing Runze Fluid Control Equipment Co., LTD.
Contactez-nous

Raccords sans brides avant-couple

Les raccords sans brides de pré-couple offrent une connexion unique pour les raccords serrés à la main par des clics lorsque la résistance du capuchon augmente jusqu'à atteindre le couple correct, il est fabriqué en PP ou en PTFE et est fourni avec un écrou de précouple et une virole pour le transfert de gaz ou de liquide. Ceux-ciRaccords filetésSont disponibles pour les diamètres extérieurs de tuyauterie de 1.6/2.0/2.5/3.0/3.2mm.

  • Pre-torque Flangeless Fittings
  • Pre-torque Flangeless Fittings

Video of Pre-torque Flangeless Fittings


预紧力详情1.jpg


Specification of Pre-torque Flangeless Fittings

Nut Specification

Nut_1.jpg

Nut_2.jpg


Ferrule Specification

Ferrule.jpg


Torque Range & Colors of Pre-torque Flangeless Fittings

Color

Blue

Yellow

Red

Nut

Pre-torque Flangeless Fittings  


Pre-torque Flangeless Fittings

Pre-torque Flangeless Fittings

Pre-torque Flangeless Fittings

Pre-torque Flangeless Fittings

Pre-torque Flangeless Fittings

Pre-torque Flangeless Fittings

Torque Range

0.11-0.15N/m

0.15-0.20N/m

0.20-0.25N/m

Operating Environment

Room Temperature and Pressure Tube wall thickness≤0.5mm

Room Temperature and Pressure               

 Tube wall thickness>0.5mm

Temperature<100℃  Pressure>0.8Mpa     

Tube WT>0.5mm

预紧力详情2.jpg

Dimension (unit: mm)


预紧力尺寸英文.jpg

Application Note of Pre-torque Flangeless Fittings

1. Choose 1/4-28 nut when receiving port is 1/4-28; Choose M6 nut when receiving port is M6.


2. Before connecting fittings, ensure the end of the tubing has a clean, square, burr-free cut. This is very important, as the square cut helps the tubing make full contact with the bottom of the mating port. Neglecting to properly cut the tubing could lead to dead volume, resulting in peak distortion such as fronting, tailing or broadening.


3. Two-Piece Fittings Installation Steps:

a. Slide the nut, followed by the ferrule, at least 3/16” (4.7625mm) from the end of the clean cut tubing

b. Insert the assembly into the receiving port, pushing the tubing into the port until it bottoms out.

c. Finger or wrench tighten the fittings until the cap comes out "click" which means properly tightened

d. After several uses (especially at high pressure) the ferrule should be replaced.


预紧力详情3.jpg


Raccords sans brides précouple connexes PDF

Product Inquiry
Produits connexes pour Raccords sans brides avant-couple
Produits
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Visit our cookie policy to learn more.
Reject Accept